Description
Fenwal 35-671922-151 24VAC Proven HSI With blower relay Ignition Control Board
Canus
Technical Specification
SPECIFICATIONS
| INPUT VOLTAGES | DESCRIPTION |
| Control | 18 to 30 VAC, 400mAmax (not including gas valve) |
| Line | 24/120/240 VAC (L1 & L2 only, voltage depends on model) |
| Thermostat | 18 to 30 VAC 30mAmax (incl. Gas Valve) |
| Pressure Switch | 18 to 30 VAC 25mAmax |
| Hot Surface Element | 24/120/240 VAC 5Amax |
| Output Ratings | |
| Inducer Fan | Relay: 15Amax or 1/3HP @ 120 or 240 VAC |
| Hot Surface Element | 5.0Amax @ 24, 120 or 240 VAC |
| Gas Valve Rating | 5.0Amax @ 24 VAC |
| Lockout & Pre-Purge indicators | 1.0Amax @ 24 VAC |
| Operating Temperature | -40 deg. F to deg. F (-40 deg. C todeg. C) |
| Flame Sensitivity | 4.0mAminimum |
| Flame Failure Response Time | 0.8 seconds max |
| Types of Gas | Natural, LP, or manufactured |
| ignitor | 24 VAC, 120 VAC, or 240 VAC mini-ignitors and silicon carbide ignitors depending on model |
| Enclosure | Gray (Noryl N-190) |
| Moisture Resistance | Conformal coated to operate non-condensing to 95% R.H. Care must be taken to protect module from direct exposure to water |
| Size with enclosure | See Figures 6 & 7 |
| Weight | 8oz including options and cover |
|
CONTROL CONFIGURATION |
|
|